Expired Study
This study is not currently recruiting Study Participants on ClinicalConnection.com. If you would like to find active studies please search for clinical trials.

Syracuse, New York 13210


Purpose:

The purpose of this study is to design a method to better localize parathyroid adenomas. This study will include approximately 6 patients who have not had surgery and another 25 patients who have already had surgery over the course of one year.


Study summary:

While a successful neck exploration for PHP is primarily dependent on the experience of the surgeon, there are currently several localizing studies available to increase success. Although the necessity of localizing studies pre-operatively for first time neck explorations is still under debate, there is no question of their importance for persistent or recurrent PHP that requires re-operation. Localizing studies in these patients have been clearly shown to reduce operating time, avoid unnecessary dissection, reduce morbidity, and improve success rate. Several modalities have been employed for localization such as ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MRI). The sensitivity of ultrasound for the preoperative detection of parathyroid adenomas has been reported to be 65-90% (1). There are however, limitations to US. Because of the sonolucent appearance of parathyroid adenomas, it is impossible to distinguish an ectopic cervical parathyroid adenoma from a pathologic lymph node. Furthermore, mediastinal parathyroid adenomas are difficult, if not impossible to visualize due to acoustic shadowing from the sternum and clavicles (2). Also, this method is very operator-dependent. MRI has a slightly higher sensitivity of 62.5-94% while CT has a poor sensitivity of only 40-44% (1). We are using dual-phase single photon emission tomography (SPECT) imaging with technetium 99m sestamibi and visual thyroid subtraction with technetium 99m as pertechnetate. This method can achieve sensitivities of 68-95% and specificities of 75-100% (1). SPECT imaging is dependent on the differential washout of sestamibi between normal thyroid tissue and abnormal parathyroid tissue. Theoretically, sestamibi will washout of normal thyroid tissue much more quickly than it will from abnormal parathyroid tissue. Therefore, SPECT imaging is usually performed immediately and then at 90 and 180 minutes after sestamibi injection. SPECT imaging, however, has several limitations, not the least of which is its inability to provide discrete anatomic detail. In addition, we will use a control group of patients who have parathyroid adenomas but who have not yet had surgery to test the efficacy of our fusion software. Our goal is to acquire MRI and SPECT imaging with fiducial markers and utilize fusion software to create a detailed anatomic map of the neck for more accurate localization of the lesion.


Criteria:

Inclusion Criteria: - Subjects who are 18 years and over - subjects who have had a failed parathyroidectomy and now presents with persistent hyperparathyroidism or recurrent hyperparathyroidism - 6 control patients with parathyroid adenomas who have not yet had surgery will be selected to test the efficacy of the software. Exclusion Criteria: - Potential female subjects who are pregnant - Any potential subject who has an implanted metallic device, stent or staples - any subject weighing 300lb


NCT ID:

NCT00639405


Primary Contact:

Principal Investigator
Michele Lisi, MD
State University of New York - Upstate Medical University


Backup Contact:

N/A


Location Contact:

Syracuse, New York 13210
United States



There is no listed contact information for this specific location.

Site Status: N/A


Data Source: ClinicalTrials.gov

Date Processed: January 23, 2018

Modifications to this listing: Only selected fields are shown, please use the link below to view all information about this clinical trial.


Click to view Full Listing

This study is not currently recruiting Study Participants on ClinicalConnection.com. The form below is not enabled.